<img height="1" width="1" style="display:none;" alt="" src="https://px.ads.linkedin.com/collect/?pid=6823746&amp;fmt=gif">
Skip to content
Flameshield 1
BUILT THE WATCO WAY

STI FLAMESHIELD®

A fire-tested aboveground storage tank featuring tight-wrap double-wall construction, engineered for protection under extreme conditions.


WATCO TANKS

FLAMESHIELD® Features:

FlameshieldModelPNG

Key Technical Advantages

Design Efficiency

Tight-wrap double-wall construction provides built-in secondary containment and interstitial monitoring capability while maintaining an efficient aboveground storage footprint

Durability

Steel construction and a tight-wrap double-wall design deliver long-term structural durability and reliable performance in demanding aboveground environments

Fuel Compatibility

Steel construction ensures compatibility with all hydrocarbons and can be configured for DEF and JetA/AV Gas applications, supporting a wide range of fuel storage requirements

Installation Considerations

The integrated tight-wrap, double-wall design provides built-in secondary containment and interstitial monitoring without the need for external containment systems



Sustainability

Constructed from recyclable steel, supporting environmental sustainability and responsible material use

Built-in Safety

The interstitial space allows for continuous monitoring, enabling early detection of potential leaks. Tanks have successfully passed a rigorous 2-hour, 2000°F fire test, validating performance under extreme conditions

Capacity Range

Available in horizontal and vertical designs with capacities of up to 35,000 gallons, accommodating diverse aboveground storage requirements

Watco Tanks Strength in Layers

FLAMESHIELD®

This tight-wrap double-wall steel design is engineered to meet the rigorous 2-hour, 2000-degree fire test. It provides built-in secondary containment and interstitial monitoring.

Flameshield Layers-01

Flameshield® Design Specifications

Standard Dimensions and Tank Capacities

Diameter Capacity Length +/- 2" Weight +/- 5%
45.5" 1,000 gal 12'-0" 2.600 lbs
72" 5,000 gal 24'-2" 9,000 lbs
96" 5,000 gal 13'-7" 9,000 lbs
96" 10,000 gal 27'-2" 15,000 lbs
96" 12,000 gal 32'-7" 18,000 lbs
120" 12,000 gal 20'-10" 18,000 lbs
120" 15,000 gal 26'-0" 21,000 lbs
120" 20,000 gal 34'-8" 27,000 lbs
120" 30,000 gal 52'-0" 39,000 lbs
Flameshield®

Installation

  • Tight-wrap double-wall construction provides integral secondary containment
  • Interstitial space supports continuous leak detection and monitoring
  • Aboveground configuration allows flexible site placement
  • Optional accessories available, including rain hoods, remote fill lines, pump platforms, observation ladders, maintenance platforms, catwalks, stairways, and custom fabrications
  • Reliable delivery scheduling with coordinated support
Flameshield AV Tank

Proven Quality Through Independent Oversight

Flameshield® tanks have successfully passed a rigorous 2-hour, 2000°F fire test, as required by Southwest Research Institute Standard SwRI 97-04, validating the performance of non-insulated tanks under extreme conditions. All tanks are backed by STICO Mutual’s 30-year limited warranty.

Watco Tanks undergoes independent third-party inspections by UL and STI, including eight unannounced audits annually. Since the inception of the inspection program over 25 years ago, Watco has maintained a flawless record — one of only three STI-certified manufacturers to do so.

Flameshield Install Photo
Available Designs:
  • Horizontal
  • Vertical
     
     
Compatible With a Wide Range of Fuels and Chemicals, Including Biodiesel and Ethanol

Flameshield® Guideline Specification

 
General
  1. Provide Flameshield® 2 hour 2000º fire‐tested double‐wall aboveground storage tanks.

Labeling
  1. Tanks shall bear the Steel Tank Institute Flameshield® identification label.
  2. Aboveground tanks shall bear the Southwest Research Institute 97‐04 label.

Manufacturer
  1. The manufacturer shall be a licensed member company of the Steel Tank Institute and subject to Steel Tank Institute’s Quality Assurance program.
Product Description
  1. Tanks shall be manufactured in accordance with Steel Tank Institute Flameshield® Standard for Aboveground Tanks.
  2. Aboveground tank primary and secondary containment (inner and outer walls) shall be manufactured in accordance and listed with Underwriters Laboratories UL 142, Standard for Steel Aboveground Tanks for Flammable and Combustible Liquids.
  3. Integral secondary containment shall be testable and provide access for interstitial leak detection monitoring.
  4. Listed supports shall be used for all horizontal, rectangular, and vertical tanks. Supports are designed for seismic loading, if necessary.

Trusted Watco Tanks Affiliates

Watco Tank Manufacturing Shot

Top U.S. Producer of STI Technologies

Watco Tanks was recognized as the largest U.S. producer of STI Technologies in 2021 and the second-largest worldwide, with over 5 million gallons built in 2021 and over 6 million gallons each in 2022 and 2023.

Download the brochure and connect with a Watco expert.